- Display information until the result
- Display the LAverage values next to the Dose Measured
Display new fields added:
Field Name Field Type Potential Values Potential Exposure beyond the sample portion of the shift* Drop Down Yes/No Analyte OEL Adjustment * Drop Down No Shift Adjustment Daily Shift Adjustment Dose Measured / LAverage 1 Alpha Numeric Value should match User entry in the system Dose Measured / LAverage 2 Alpha Numeric Value should match User entry in the system Dose Measured / LAverage 3 Alpha Numeric Value should match User entry in the system Result Type Drop Down Dose LAverage LTWA 1 Numeric Value should match user entry in the system LTWA 2 Numeric Value should match user entry in the system LTWA 3 Numeric Value should match user entry in the system LPeak Numeric Value should match user entry in the system
Info | ||
---|---|---|
| ||
Contact your ProcessMAP support team for changing the custom settings for displaying/hiding the Potential Exposure beyond the sample portion of the shift field |
...
Info | ||
---|---|---|
| ||
If the data entered for the free text entry fields, the system will create a new one. For Employee creation, the system will create a new one if the Employee is not available (Active/Inactive) during import with the following details:
|
This change will impact the following:
Reports | Others |
---|---|
IH Summary Report | Work Area Creation - Foundation setup |
Employee Notification Report | Task Creation - Foundation setup |
IH Query Report | Cognos |
All Reports Central Report |
Info | ||
---|---|---|
| ||
Contact your ProcessMAP support team for changing the custom settings for the following:
|
Mandatory/Non-Mandatory/Hide fields in QRA, Sample Plan, Sample, Action item, SEG, Import noise and Chemical – PMP - 24964
The application has been enhanced to have the following fields configured as mandatory/non-mandatory/hidden throughout the screens in the application (Add/Edit/Listing/Reports/Import Template):
Field Name |
---|
Department (Location) |
Job Classification |
Task |
Work Area |
Task Classification |
Assessment Description/ Summary |
PPE |
Admin Controls |
Engineering Controls |
- For Optional Filters in Report: If the status is set to hide in custom setting, the filter will be visible in optional filter; however, the drop down for the field would have no values available
- For Mandatory Filters in Report: If the status is set to hide in custom setting, the hidden field will not be displayed
- In the Report output, the columns/sections for the hidden field(s) would not displayed
Impacted Reports
# | Reports Central/Other | Field in Search Screen | Fields in Report |
---|---|---|---|
1 | Breakdown by Samples by Result Category -By Facility | Engineering Control, PPE Control, Admin Control | None |
2 | Breakdown by Samples by Sample Status -By Facility | Engineering Control, PPE Control, Admin Control | None |
3 | Chemical Details Report | Sample Column Selection > Controls | Department, Engineering Control, PPE Control, Admin Control |
4 | Exception report | Department | Department |
5 | IH Query Report | Job Classification, Task Classification, Admin Controls, Engineering Controls, Action Item Description | Department, Work Area Function, Task, Job Classification & title, Task Classification, Admin Controls, Engineering Controls, PPE Control |
6 | Noise Details Report | Sample Column Selection > Controls | Department, Engineering Control, PPE Control, Admin Control |
7 | Qualitative Risk Assessment Detailed Report | None | Department ,Task, Task classification, Work Area, Job classification, Assessment Description |
8 | Sample Plan Record Report | Department, Task, Work Area, Job classification | Department, Work Area, Task, Job classification |
9 | Sample Report | Department, Task, Work Area, Job classification | Department ,Work Area, Task |
10 | Employee Notification | NA | Engineering Control, PPE Control, Admin Control |
11 | IH Summary Report | NA | Department, Engineering Control, PPE Control, Admin Control, Work Area, Task, Job Classification |
Info | ||
---|---|---|
| ||
Contact your ProcessMAP support team for changing the custom settings for the fields in QRA, Sample Plan, Sample, Action item, SEG, Import noise and Chemical |
Controls Comment in IH summary & Employee Notification Report - PMP - 25741
The application has been enhanced by adding the control comments in the IH Summary and Employee Notification.
Employee Notification Letter:
IH Summary:
Direct Monitoring Gas & Vapours and Detector Tubes– PMP - 24964
The duration type has been reordered for Direct Monitoring Gas & Vapours and Detector Tubes.
Direct Monitoring - Gases and Vapors | Direct Monitoring - Detector Tube |
---|---|
- Only the selected durations will be displayed in the Results Category
- Users will be able to manually capture the OEL based on their preferred type.