Potential exposure of the shift in Noise Equipment Screen – PMP - 24964
Previous state: The system has been enhanced to consider the "Potential Exposure beyond the sample portion of the shift" for Noise (dosimeter and Laverage). A new field for "Potential Exposure beyon the sample portion of the shift" has been added where the user will be able to select Yes/No from the Sample Activity screen.
A new filed for "Potential Exposure beyond the sample portion of the shift" has been added to the Sample-Import Noise template.
Calculation for Noise:
- If "Potential Exposure beyond the sample portion of the shift" = No
- Dose Calculated Results = Dose Measured
- If "Potential Exposure beyond the sample portion of the shift" = Yes
- Dose Calculated Results = (Dose Measured) ((Shift Length*60)/Sample Duration in minutes))
Info | ||
---|---|---|
| ||
Contact your ProcessMAP support team for changing the default value as Yes/No for "Potential Exposure beyond the sample portion of the shift" |