New and Improved Features


Sound level meter detail modification – PMP-8256

The system will now have a new option as "Contractor Equipment Used" for Sound Level Measurement. During the Sampling process for sound level meter The Extra Equipment fields will show as below:

  • This field will have 2 options: Yes / No for Contractor Equipment Used
    • If Contractor Equipment Used is selected as Yes, then Equipment Name/ID, Manufacturer, Model and Serial fields will not be displayed 



    • If Contractor Equipment Used is selected as No,  then the system will display the Manufacturer, Model, and Serial fields
      • The Manufacturer, Model, and Serial fields are non-editable and are auto generated when an associated equipment name/ID is searched.
    • The Equipment Name/ID pick list will pull the data from Module Setup >>Additional IH Equipment>>Equipment Type - Sound Level Meter


Noise Import Modification – PMP - 11596

The Sample Noise Import has been enhanced to: 

  • Display information until the result
  • Display the LAverage values next to the Dose Measured
  • Display new fields added: 

    Field NameField TypePotential Values
    Potential Exposure beyond the sample portion of the shift*Drop DownYes/No
    Analyte OEL Adjustment *Drop DownNo Shift Adjustment Daily Shift Adjustment
    Dose Measured  / LAverage 1Alpha NumericValue should match User entry in the system
    Dose Measured  / LAverage 2Alpha NumericValue should match User entry in the system
    Dose Measured  / LAverage 3Alpha NumericValue should match User entry in the system
    Result TypeDrop DownDose LAverage
    LTWA 1NumericValue should match user entry in the system
    LTWA 2NumericValue should match user entry in the system
    LTWA 3NumericValue should match user entry in the system
    LPeak NumericValue should match user entry in the system




Configurations for Potential Exposure beyond the sample portion of the shift

Contact your ProcessMAP support team for changing the custom settings for displaying/hiding the Potential Exposure beyond the sample portion of the shift field 


Chemical Import Tool Modification – PMP - 24690

The Chemical Import tool has been enhanced to: 

  • Include new field: Post Calibraation flow rate
  • Make the following fields non-mandatory:
    • Department
    • Task classification
    • Media Expiration date
    • Personal Protection Equipment
  • Convert the following drop down fields as free text entry: 
    • Work Area
    • Task
    • Employee


Free Text Entry Configurations

If the data entered for the free text entry fields, the system will create a new one. 

For Employee creation, the system will create a new one if the Employee is not available (Active/Inactive) during import with the following details:

  • Employee ID:
  • First Name
  • Last Name
  • Employee Type: Employee
  • Status = Inactive


This change will impact the following:

ReportsOthers
IH Summary ReportWork Area Creation - Foundation setup
Employee Notification ReportTask Creation - Foundation setup
IH Query ReportCognos
All Reports Central Report 

Field Configuration Changes

Contact your ProcessMAP support team for changing the custom settings for the following: 

  • Show/Hide the Post calibration flow rate field 
  • Configure the following fields as Drop Down or Free Text Entry
    • Work Area
    • Task