Users will be able to create a new IH sample. 

Business Rules

  • Sample details should have been created and saved.
  • Depending on the specific Company business rules, the selection of certain fields may or may not be mandatory.

Step-by-step Instructions:

  1. Click on the Modules icon.
  2. Click on the Industrial Hygiene menu item.
  3. Click on the Manage Sample menu item.

  4. Click on the IH Log Number hyperlink.

  5. In Sample Equipment field, Click on the Add button.

  6. In Calibration Equipment ID field and select Noise Calibrator from the pick list.
  7. Complete all the fields and Click on the Save button.



    Sample Equipment Information

    FieldsDescription
    Monitoring Equipment Owned By

    This field will default to the current location and picklist of Equipment details is only associated with Default Location

     i. Corporate – This is equipment managed by the Corporate Team
    ii. Borrowed from Other Site – This is equipment shared from other location (user must know what location to select appropriate equipment)
    iii. Contractor – No equipment details are required based on this selection

    Equipment Details

    Field Description
    Air Monitoring Equipment IDEquipment Type should be selected from the pick list.
    Air Monitoring Equipment NameSystem will auto-populated
    ManufacturerSystem will auto-populated
    ModelSystem will auto-populated
    SerialSystem will auto-populated
    Was a Size selective Sampler Used

    It has two options Yes & No.

    Yes : Size Selective Sampler should be mentioned.

    No : No need to mention.

    Calibration Equipment Details

    Field Description
    Calibration Equipment IDCalibration Equipment Type should be selected from the pick list.
    Calibration NameSystem will auto-populated
    ManufacturerSystem will auto-populated
    ModelSystem will auto-populated
    SerialSystem will auto-populated
    Date of Last Factory / Traceable CalibrationSystem will auto-populated
    Factory / Traceable Calibration Valid UntilSystem will auto-populated

    Sample Calibration Details

    Field Description
    Flow RateUnits of the flow rate is to be selected
    Pre Calibration DateStart of the Calibration Date.
    Post Calibration DateEnd of the Calibration Date.
    Pre Calibration Flow RateFlow Rate before starting of Calibration.
    Post Calibration Flow RateFlow Rate at end of Calibration.
    Pre Post Calibration Difference (%)System will auto-populated
    Average Flow RateSystem will auto-populated
    Total VolumeSystem will auto-populated

    Sample Activity Details

    Field Description
    Associated BlankSelect the Associated Blank from the pick list.
    Shift LengthSelect the Lenght (in Hours) of the shift
    Analyte OEL Adjustment

    Select the appropriate Option of :

    Day Shift Adjustment or No Shift Adjustment

    Was there potential exposure beyond the sample portion of the shiftSelect the appropriate Option of : Yes or No
    Split Sample

    If the Sample has to be slipt then check the check box 

    If not leave it as blank

    Period of sample Start TimeStart time of the Sample in (HH/MM)
    End TimeEnd time of the Sample in (HH/MM)
    Media1Select the Media from the pick list
    Media Lot/Serial NumberMedia Lot/Serial Number should be mentioned
    Calculated TimeSystem will auto-populated
    Override Calculated Time?

    It has two options 

    If Yes is selected : Then Official time should be mentioned

    If No is Selected : Nothing to mention. 


Field Information Table

Field NameDetails/Description