New and Improved Features
Product Level Change
Configurable:
- PMP-92800: Ability to Enter Sample Results in units other than mg/m3 and have the application do the conversion.
- PMP-92798 - Make noise adjustment to the dose results as per Australia requirements
Product Level Change
PMP-92794: Ability to Select OSHA PEL as a Noise Setting in the 'Regulatory Name' Dropdown
Configurable: No
- Title: NA
- Public/Private: NA
- Default: NA
Existing System:
Current functionality does not allow for the OSHA PEL to be selected from the dropdown menu under Duration Type for a Noise Dosimeter sample. OSHA PEL noise setting is a typical noise setting and should be one of the options.
Purpose:
To be able to OSHA PEL as one of the dropdown options under Regulatory Name.
Enhanced System:
OSHA PEL to be added to the dropdown Menu of ‘Regulatory Name’.
Impacts: No Impacts
Configurable:
PMP-92800: Ability to Enter Sample Results in units other than mg/m3 and have the application do the conversion.
Configurable: Yes
- Title: Enable UOM Calculation
- Public/Private: Private
- Default: Product
Existing System:
Sample Results are supposed to be entered by the lab in mg/m3, but this does not always happen causing erroneous data. Users as well as Labs enter the data in other units such as PPM or UG/m3 but the system doesn't identify these units. There is no unit conversion performed by the IH Module.
Purpose:
To be able to calculate results in units other than mg/m3.
Enhanced System:
User Interface will now have an additional column for 'Lab Concentration' which will display the converted Unit of measurement. System will take these columns into consideration for calculating the sample result.
Impacts: No Impacts
PMP-92798: IH: Make noise adjustment to the dose results as per Australia requirements
Configurable: Yes
- Title: Enable Aus Noise Adjustment
- Public/Private: Private
- Default: Product
Existing System:
Australian Set of Standards that force an extra dba to be added to the result when the user works an extended shift beyond 8 hours. The IH Module only performs calculations based on the shift start time and end time (THE EXPOSURE TIME) AND DOSIMETER RUNTIME. There is no adjustment based on the length of the shift.
Purpose:
To be able to calculate results as per Australia requirements.
Enhanced System:
If the customer enters a shift start time and end time that indicates the shift is 10 hrs (600 minutes) or more, the calculated L dB(A) would display at L dB(A) plus 1 or 2 or 3 based on the Australia requirements.
Impacts: No impact