Skip to end of banner
Go to start of banner

Manage Sample Results – Chemicals

Skip to end of metadata
Go to start of metadata

You are viewing an old version of this page. View the current version.

Compare with Current View Version History

« Previous Version 2 Next »

Users will be able to create a new IH sample. 

Business Rules

  • Sample details and Sample Equipment information must be completed prior to reporting results.


Sample Results – There are 3 means of how Sample results may be populated. This Help Guide Focusing on the third scenario below which is manually adding Sample Results

1. Sample Results may be imported through the Lab Interface set up within the system. If results are imported through the feed, users can follow this document to make any changes to those results.

2. Sample Results may be imported via the Import Excel Spreadsheet functionality. If results are imported through the Excel File, users can follow this document to make any changes to those results.

3. Sample Results may be added manually. This Help Guide provides direction on how to perform this activity


Step-by-step Instructions:

  1. Click on the Modules icon.
  2. Click on the Industrial Hygiene menu item.
  3. Click on the Manage Sample menu item.



  4. Click on the IH Log Number hyperlink.



  5. In Sample Result section, Click on the Add button.



  6. Complete all the fields and Click on the Save CIH button.





    Employee Information Key Fields

    FieldDescription
    Substance/AgentThis information is prepopulated from the Chemical selected in Sample Details
    Lab Amount This is the amount the lab extracts from the sample. Units are standardized.
    Lab ConcentrationThis is the result generated from the Lab based on the Sample Volume.
    Sample Result

    This is the Lab Concentration applying any adjustment based on Exposure Time.

    If number is different, user must have selected “No” to the question “Was there potential exposure beyond the sample portion of the shift” in the Sample Activity Details.

    OEL / Adjusted OEL

    OEL : The OEL will be pre-populated from the Chemical Library and will be based on the Lowest define limit as established by either ACGIH, Country Limit or State / Province Limit.

    i. If there is no display of a limit, it is not available and the system will not be able to compare results.

    Adjusted OEL : – If sampling based on a shift other than an 8 hour shift, user has the abilty to adjust the OEL Limit. This is based on a field in the Sample Activity details section called “Analyte OEL Adjustment”.

    If user selects “Yes” and chooses “Daily Shift Adjustment”, the system will calculate down the OEL value based on a 10 or 12 hour shift.

    Detection LimitUser will be required to add the numeric value and the corresponding units.
    Detection CodeOptions are to leave blank or select less than “<”. If value is “<”, the assumption is the Lab Amount was less than the detectible limit. This will also impact the mixture calculation if the sample is for multiple chemicals. The analyte with “<” will not count against the Mixture formula.
    Category 

    The Sample Result will be compared against the Adjusted OEL Value. The following criteria has been established:
    1. Less than (<) 50% of the Action Limit < Action Level Green 
    2. Equal to or Greater than (≧) 50% and less than 100% > Action Level Yellow 
    3. ≧100% Limit with proper PPE in use Over Standard Orange
    4. ≧100% Limit Insufficient PPE in use Over Exposure Red

    Lab Details

    FieldDescription
    Lab NameThe lab is required but should be pre-configured by the IH Corporate Team.
    Lab AnalystLab Analist name should be mentioned.
    Lab Sample IdRequired and refers to the Sample ID that the Lab uses
    Date ReceivedDate in which the Lab Received the Physical Sample(s)
    Date AnalyzedDate in which the Lab Analyzed the Sample (s)
    Analytical MethodsThe method is required but should be pre-configured by the IH Corporate Team.
    Lab CommentsIf any comments are there. those are to be filled here

    Sample CIH Information

    FieldDescription
    CIH Approval / InvalidationUser must have permission set to Approve or Invalidate.
    Sample Approved Fields
    Approved DateDate when the Sample was approved.
    Approved ByPicklist will be based on system users.
    Corrective Action Required ?If Sample is an “Over Exposure” Classification, then Corrective Action box will default to checked. If box is checked a default Corrective Action will be created.
    Sample Invalidated Fields
    Invalidated DateDate when the Sample was approved.
    Invalidated ByPicklist will be based on system users.
    CommentThe invalidated comment is required but should be pre-configured by the IH Corporate Team.
    Corrective Action Required ?Not applicable for invalidated samples and will be grayed out.


Generate Employee Notification Letters – Employee Notification Letters may ONLY be generated AFTER CIH Approval

  • No labels