Manage Sample Results - Noise
Manage Sample Results - Noise
Users will learn how to add/manage Sample Results - Noise.
Business Rules
- Users must have created the Sample Details.
- Sample Equipment section must be Completed.
On this page: |
---|
Step-by-step Instructions
Adding Sample Results - Noise from an existing Noise Sample
- Click on Modules.
- Navigate to Industrial Hygiene.
- Select Manage Samples menu item.
- Click on the hyperlinked IH Log Number from the Sample List Screen.
- Click on the Add button located to the right of Sample Result.
- Complete the Result Noise Equipment section. (Refer to Result Noise Equipment Information for more details)
- Click on the Save Result button.
Step by step Instructions
Completing the Sample CIH Information
CIH Information Business Rule
- User must have permission set to Approve/Invalidate
- From the Sample Dashboard Summary, expand the Sample Result section. (Refer to the Comparison to Limits section for criteria for color-coding.)
- Click on the hyperlinked Results/Projected.
- Expand the Sample CIH information section.
- Approve/Invalidate the Sample.
- Complete the required fields. (Refer to Sample approved for additional information on Approved Date and Approved By fields.)
- Approved Date*
- Approved By*
- Click Save CIH button.
- Click Ok button on the confirmation window.
Result Noise Equipment Information
- Dose Measured - This field is used to generate the Results. System will calculate results applying Dose Measured and applicable formula associated with Doubling Exchange, Threshold & Criteria.
- L Peak - This field is for Information Usage Only. Only numeric values are permitted.
- Result Details section - This section is non-editable. All values will be populated, once the user save the Dose Measured field.
Comparison to Limits Configuration
The Sample Result will be compared against the Adjusted OEL Value. The following criteria has been established:
Results | OEL | Color |
---|---|---|
Less than (<) 50% of the Action Limit | < Action Level | Green |
Equal to or Greater than (≧) 50% and less than 100% | > Action Level | Yellow |
≧100% Limit with proper PPE in use | Over Standard | Orange |
≧100% Limit Insufficient PPE in use | Over Exposure | Red |
Sample Approved Fields Information:
Field Name | Description |
---|---|
Approved Date | Date when the Sample was approved. |
Approved By | Pick list will be based on system users. |
Corrective Action Required? |
|
19.1 Update
- In IH Report Email if below check boxes are selected, then system to send email without any alert message even if "To" field is blank
- Send to employee
- Send to employee supervisor
- Applicable for all physical and chemical samples
- If employee is not mandatory in Sample Detail and user has not entered any employee or supervisor ,it should show the same validation message if To field is blank and Send to employee and supervisor is selected.
19.1 Update
- If a unprocessed COC file is deleted in system then Sample status would auto-change from Sent to Lab to Not Sent to Lab
- A Processed COC or a manually edited sample whose status has changed to result recieved , if deleted the status would not change .It would remain as Result Received
19.1 Update
- IH Sample Report in Multilingual